For SHE and ventilation
Special features:
- Pressure and tractive forces up to 1500 N
Technical data | ||
Version | M1/...-1500N/LA/EV1/SHE | M1/...-1500N/SG/EV1/SHE |
Electrical properties | ||
Rated voltage | 24 V DC (-20 % /+25 %) | |
Permissible ripple voltage | 2 Vss | |
Nominal current | 2.5 A | |
Cut-off | internal | external via synchronous module |
Class of protection | III | |
Mechanical properties | ||
Stroke length aprox. | 300, 500, 750 and 1000 mm | |
Pressure force | max. 1500 N | |
Tractive force | max. 1500 N | |
Locking force | 2000 N | |
Running speed | approx. 11.6 mm/s | approx. 9.8 mm/s |
Duty cycle | ED 30 (10 min) | |
Service life | > 10.000 cycles | |
Dimension (L x W x H) | (stroke + approx. 410 mm) x Ø 50 mm | |
Electrical connection | ||
Connection | 2 x 1.5 mm² | 2 x 1.5 mm² + 3 x 0.5 mm² |
Installation and ambient conditions | ||
Ambient temperature range | –5 °C up to +75 °C | |
Protection category | IP 54 |
Depending on the control panels used, increased currents in the starting torque must be taken into account when dimensioning the power supply and the cable cross-sections of the motor supply lines. Reliable operation is guaranteed when connected to appropriate control units from the same manufacturer. For operation on control systems from other manufacturers, conformity.
Subject to technical changes; illustrations not binding.for functional safety must be requested.
voltage drive: | 24 V DC |
Application: | SHE & Ventilation |
Series: | M1 |
- Do you have any questions concerning this product?
- Heinze LV-Texte Singlebetrieb
- Heinze LV-Texte Synchronbetrieb
- Further products by Kingspan STG GmbH