For ventilation
Special features:
- Operated with 230 V mains voltage and is therefore without ballast unit
- Potential-free contact for message "Not CLOSED" (contact closes when leaving position CLOSED)
Technical data | |
Version | M3/...-500N/LA/EV1/AC |
Electrical properties | |
Rated voltage | 230 V AC/50 Hz (-15 %/+10 %) |
Nominal current | approx. 0.2 A |
Cut-off | electronic load cut-off, built-in |
Class of protection | II |
Mechanical properties | |
Stroke length aprox. | 82, 300, 500 and 750 mm |
Pressure force | max. 500 N |
Tractive force | max. 250 N |
Locking force | 2000 N |
Running speed | approx. 10 mm/s |
Duty cycle | ED 30 (10 min) |
Service life | > 10.000 cycles |
Dimension (L x W x H) | (stroke + approx. 133 mm) x 82.5 x 41 mm; |
Electrical connection | |
Connection | 5 x 0.75 mm², legth approx. 1.60 m, grey |
Installation and ambient conditions | |
Ambient temperature range | –5 °C up to +75 °C |
Protection category | IP 44 |
Depending on the control panels used, increased currents in the starting torque must be taken into account when dimensioning the power supply and the cable cross-sections of the motor supply lines. Reliable operation is guaranteed when connected to appropriate control units from the same manufacturer. For operation on control systems from other manufacturers, conformity for functional safety must be requested.
The drives are equipped with an integrated switching power supply for operation on 230 V AC mains voltage. Suitable switching and relay contacts must therefore be used to control the drives.
Subject to technical changes; illustrations not binding.
With our free tool, you can find customized suggestions for the right drive for your requirements in the façade or on the roof in no time at all based on the window automation data you enter
voltage drive: | 230 V AC |
Application: | Ventilation |
Series: | M3 |
- Do you have any questions concerning this product?
- Heinze LV-Texte
- Further products by Kingspan STG GmbH
Welche Konsolen und Flügelböcke brauche ich für eine Montage an einer Lichtkuppel?
- Klemmrahmenkonsole K28/B, max. zulässige Kraft 650 N
- Flügelbock FB9/G