Synchronous Module SM3

Preis auf Anfrage

Prices incl. VAT plus shipping costs

Version:

  • 13368011060
  Technical data Version SM3  Electrical... more
Product information "Synchronous Module SM3"

 

Technical data

Version

SM3 

Electrical properties

Rated voltage

24 V DC (-20 % /+25 %)

Permissible ripple voltage

2 Vss

Cut-off

integrated, electronic load cut-off, switch-off value dependent on the connected drive, see also planning help

Class of protection

III

Mechanical properties

Dimension (L x W x H)

110 x 66.7 x 110 mm

Electrical connection

Connection

2 x 1.5 mm², 3 x 0.5 mm²

Connection clamp

max. 6 mm² for motor supply cable, max. 2.5 mm² for transmission, max. 1.5 mm² for drives and signal lines

Safety shutdown In the event of undervoltage < 17.5 V, wire breakage, blockade after 5 activations in the same direction
Max. Cable length between control unit and drive 10 m

Potential-free signaling contact

Ohmic load, max. 1A/60 V DC (SELV)

Installation and ambient conditions

Ambient temperature range

–5 °C up to +65 °C

Protection category

IP 20

 SM3-types

  • 1.0A/1.0A/A for M2 500 N
  • 1.0A/1.0A/A for M2 1000 N
  • 1.0A/1.0A/C for M9 650 N
  • 1.1A/1.1A/A for M9 1000 N
  • 2.0A/2.0A/A for M9 1500 N
  • 3.5A/2.5A/A for M1 1500 N
  • 3.5A/2.5A/B for M1 1000 N
  • 4A/2.5A/A for M1 2000 N

Depending on the control panels used, increased currents in the starting torque must be taken into account when dimensioning the power supply and the cable cross-sections of the motor supply lines. Reliable operation is guaranteed when connected to appropriate control units from the same manufacturer. For operation on control systems from other manufacturers, conformity for functional safety must be requested.

Related links to "Synchronous Module SM3"
Available downloads:
Fragen und Antworten mehr
Hier finden Sie die häufigsten Fragen und die dazugehörigen Antworten zu diesem Artikel.
Eine Frage zum Artikel stellen

Die mit einem * markierten Felder sind Pflichtfelder. Die E-Mail wird nicht veröffentlicht.

Vielen Dank für das Stellen einer Frage. Wir werden versuchen, diese schnellstmöglichst zu beantworten.
Read, write and discuss reviews... more
Customer evaluation for "Synchronous Module SM3"
Write an evaluation
Evaluations will be activated after verification.

The fields marked with * are required.

I have read the data protection information.

Viewed