1.2 Chain drives

The 24 V chain drives for smoke extraction and ventilation can be mounted in a concealed or visible manner on the window profile. These drives are suitable for applications with up to 1200 N per drive and opening widths of up to 800 mm. The 230 V AC ventilation drives are available with a force of up to 600 N per drive and opening widths of up to 800 mm. Two drives can be mounted on one window element as a twin or tandem.

The 24 V chain drives for smoke extraction and ventilation can be mounted in a concealed or visible manner on the window profile. These drives are suitable for applications with up to 1200 N per... read more »
Close window
1.2 Chain drives

The 24 V chain drives for smoke extraction and ventilation can be mounted in a concealed or visible manner on the window profile. These drives are suitable for applications with up to 1200 N per drive and opening widths of up to 800 mm. The 230 V AC ventilation drives are available with a force of up to 600 N per drive and opening widths of up to 800 mm. Two drives can be mounted on one window element as a twin or tandem.

1 from 2
No results were found for the filter!
Chain Drive KCDM
Chain Drive KCDM
For SHE and ventilation Special features: Push and pull force up to 450 N Attachable function modules for 24 V DC SHE, 24 V DC ventilation, 230 V AC ventilation Projection widths 400, 600, 800 and 1000 mm OPEN and CLOSE signaling, potential-free signaling contacts integrated in the SHE function module Simple installation using the supplied drilling machine Configuration...
Preis auf Anfrage
Chain Drive KCDL
Chain Drive KCDL
For SHE and ventilation Special features: Push and pull force up to 600 N, particularly suitable for use in the roof area Attachable function modules for 24 V DC SHE, 24 V DC ventilation, 230 V AC ventilation Projection widths 400, 600, 800 and 1000 mm OPEN and CLOSE signaling, potential-free signaling contacts integrated in the SHE function module Simple installation using...
Preis auf Anfrage
Cain drive LM/2/.../TD/.../AC
Cain drive LM/2/.../TD/.../AC
For controlled natural ventilation Special features: Versatile 230 V drive solution with two drives with up to 2 x 200 N push and pull force and external upstream unit for wide sashes, flaps and skylights Technical data Version LM/2/Tandem/350-200N/.../AC LM/2/Tandem/500-200N/.../AC Electrical properties rated voltage 230 V AC, 50 Hz (±10%) Nominal current approx. 0,28 A...
Preis auf Anfrage
Chain Drive CDi/...-300N/SW/DC2
Chain Drive CDi/...-300N/SW/DC2
For SHE and ventilation Special features: Parallel operation of several drives on one sash with integrated tandem (CDi) or synchronous control (CDi/EasyDrive/2) possible Technical data Version CDi/...-300N/SW/DC2 Electrical properties Rated voltage 24 V DC (-20 % /+25 %) Permissible ripple voltage 2 Vss Nominal current 0.6 A at 200 N Cut-off integrated, electronic load...
Preis auf Anfrage
Chain Drive CDi/...-300N/EasyDrive/2/SHE
Chain Drive CDi/...-300N/EasyDrive/2/SHE
For SHE and ventilation Special features: Up to 4 drives plus 2 locking drives can be synchronized Synchronization and reference run can be carried out without EasyDrive software Stroke, speed, force: separately adjustable for OPEN/CLOSE via EasyDrive software Integrated signaling contact, function configurable Two connection terminals for simple connection between the...
Preis auf Anfrage
Chain Drive LM/2/.../200N/.../AC
Chain Drive LM/2/.../200N/.../AC
For controlled natural ventilation Technical data Version LM/350-200N/.../AC LM/500-200N/.../AC Electrical properties Rated voltage 230 V AC, 50 Hz (±10%) Permissible ripple voltage - Nominal current approx. 110 mA Cut-off integrated, electronic load cut-off Class of protection I Mechanical properties Stroke length aprox. 350 mm 500 mm Pressure force 150 N (see force-path...
Preis auf Anfrage
Chain Drive EM/...-300N/.../AC **Product discontinuation**
Chain Drive EM/...-300N/.../AC **Product...
For SHE and ventilation Special features: Operator with low installation depth and slim, linear housing Technical data Version EM/2/...-300N/.../AC Electrical properties Rated voltage 230 V AC (-10 %/+10 %) Permissible ripple voltage -/- Nominal current 0,16 A Cut-off integrated, electronic load cut-off Class of protection II Mechanical properties Stroke length aprox. 327,...
Preis auf Anfrage
Chain Drive LM/EasyDrive/2/.../.../SHE
Chain Drive LM/EasyDrive/2/.../.../SHE
For SHE and ventilation Special features: Up to 4 drives plus 2 locking drives can be synchronized Synchronization and reference run can be carried out without EasyDrive software Stroke, speed, force: separately adjustable for OPEN/CLOSE via EasyDrive software Integrated signaling contact, function configurable Two connection terminals for simple connection between the...
Preis auf Anfrage
Chain Drive LM/2/.../.../SHE
Chain Drive LM/2/.../.../SHE
For SHE and ventilation Special features: Parallel operation of several drives on one sash with integrated tandem (LM/2) or synchronous control (LM/EasyDrive/2) possible Technical data Version LM/2/350-200N/.../SHE LM/2/500-200N/.../SHE Electrical properties Rated voltage 24 V DC (-20 % /+25 %) Permissible ripple voltage 2 Vss Nominal current 0.5 A at 200 N Cut-off...
Preis auf Anfrage
Chain Drive CDs/...-300N/SHE
Chain Drive CDs/...-300N/SHE
For SHE and ventilation Special features: Stroke, speed, force: separately adjustable for OPEN/CLOSE via software Running speed in OPEN and CLOSE direction can be reduced to Reversing on detection and overload in CLOSE direction Synchronous operation of up to 4 drives and additional connection of up to two latch motors Teach-in of: Closing position and opening width, as well...
Preis auf Anfrage
Chain Drive EM/EasyDrive/2/...-300N/.../SHE **Product discontinuation**
Chain Drive EM/EasyDrive/2/...-300N/.../SHE...
For SHE and ventilation Special features: Up to 4 drives can be synchronized Synchronization and reference run can be carried out without EasyDrive software Stroke, speed, force: separately adjustable for OPEN/CLOSE via EasyDrive software Integrated signaling contact, function configurable Two connection terminals for simple connection between the drives Adjustable sealing...
Preis auf Anfrage
Chain Drive EM/2/...-300N/.../SHE **Product discontinuation**
Chain Drive EM/2/...-300N/.../SHE **Product...
For SHE and ventilation Special features: Operator with low installation depth Tight seal via electronically defined contact pressure Technical data Version EM/2/...-300N/.../SHE Electrical properties Rated voltage 24 V DC (-20 %/+25 %) Permissible ripple voltage 2 Vss Nominal current 0.8 A at 300 N Cut-off integrated, electronic load cut-off Class of protection III...
Preis auf Anfrage